Aptifold

Gravitational waves Research lead

How many chances did the black hole get?

After two black holes merge, the new one rings. One of its tones can fade in milliseconds. That makes the first sample of a fit surprisingly consequential.

If you listen from a few different moments and keep the best fit, how often can the noise pass for a second tone?

Interactive experiment

Move the start

The fitter scores how much a rapidly fading second tone improves the fit. Each new start discards some early samples. Drag either chart or use the slider to keep the data fixed and change where the fit begins.

Signal and fits

Simulated strain in noise units

TraceOne-tone fitTwo-tone fit

What a second tone buys

Improvement in the two-detector fit, Δχ²

Single-start cutoffSearch cutoffStart in current rule

Measured background

What does 1% become?

We set a threshold that one planned start clears 1% of the time in ideal Gaussian noise. Then we applied that same threshold to each search rule on held-out detector noise.

More time, more cuts

4,736 held-out windows · same cutoff in every cell

Choose a cell to compare that rule across the page.

Threshold crossing rate at Δχ² = 13.2767
SpanEvery fourth sampleEvery sample
1.95 ms2.60% · 3 starts4.46% · 9 starts
6.84 ms5.83% · 8 starts11.63% · 29 starts

One planned start 1.06%

Noise above each cutoff

Share of noise windows crossing each cutoff, log scale

One startSelected search29 independent starts

Spacing matters. At the benchmark, 8 starts spread over 6.84 ms crossed the cutoff more often than 9 packed into 1.95 ms. Filling in the wide interval nearly doubled its crossing rate again.

Inside the fit

What does the next sample change?

Each detector fits two components of the overtone, sine and cosine. Move the cut by one sample and one combination of those components stays exactly shared in this model. Move farther and the two fits can diverge.

Score correlation by separation

Hanford + Livingston, fitted Gaussian noise model

Fixed reference, 0 msWhite-noise comparison

Compare two fits

A value of 1 means the two fits use the same noise component. The factors come from the model geometry. They describe how the scores depend on one another.

The tradeoff

When is a wider search worth it?

Give every rule its own cutoff, targeting 1% false alarms. Add a known overtone to the held-out LIGO noise. If your planned cut is late, it can miss much of a tone that a wider search still gets to hear.

Recovery at matched error targets

Same injections, separate cutoffs

One planned startSelected search

What if you start late?

Strength means the network signal-to-noise ratio of the part of the overtone the fundamental cannot fit, measured at the earliest start. The injection decays throughout the available window.

For review

What the test establishes

Calibrate the search you actually ran. Report the span, the spacing and how you selected the start. A benchmark for one planned fit can become permissive when applied to the best of many.

Where the data came from

We used public 4 kHz Hanford and Livingston strain around GW250114. After applying shared data-quality requirements and excluding 32 seconds on each side of the merger, we assigned disjoint 8-second blocks to noise estimation, cutoff calibration and held-out testing. The primary result compares 4,736 paired windows. The cutoffs for the power test come from 2,432 other pairs. Each fit has a common end roughly 32 ms after the first candidate start.

The GW250114 data release comes from the Gravitational Wave Open Science Center and is available under CC BY 4.0. The instrument replays a small selection of held-out excerpts. It deliberately opens on a case that illustrates why the threshold matters when you choose a recorded trace.

The two-tone score and overlap calculation

Use two decaying sinusoids per detector, each with free real sine and cosine coefficients. Our fixed 220 fundamental is 249.89 Hz with a 4.08 ms amplitude e-folding time. The 221 overtone is 244.37 Hz with a 1.34 ms amplitude e-folding time. We use the discovery release’s nominal detector-frame mass and spin and Berti’s fitting coefficients.

We difference data and templates twice to remove constant and linear drift, and whiten using the covariance of each retained suffix. Let Qdi contain the two whitened overtone columns left after projecting out the fundamental at detector d and start i. The columns are orthonormal. The score is the sum of their squared projections over both detectors.

Si = Σd ‖QdiT ydi‖²,   Sscan = maxi ∈ search Si

Si is χ² with four degrees of freedom under known Gaussian covariance and independent detectors. The independence curve uses 1 − (1 − p)k as a reference for k imagined independent trials. With overlapping windows we estimate the actual maximum distribution instead.

In the full whitened sample space, let Bi be the available linear combinations after excluding samples before cut i and projecting out the fundamental. Then Bi+1 sits inside Bi with codimension one. The two-dimensional extra-tone subspace at i+1 is the orthogonal projection of the subspace at i into Bi+1. At least one direction survives unchanged. For two independent detectors the overlap between these shared directions alone contributes at least one half to the adjacent score correlation. This identity assumes nested cuts, fixed templates and a common covariance.

Download the replay and exact source identifiers

Use Python 3.12 with NumPy 2.3.5, SciPy 1.16.3 and h5py 3.16.0. Download the 4 kHz, 4096-second HDF5 release for each detector and keep the original filenames. The record supplies direct data URLs, SHA-256 checksums, sample partitions, scores and curve values.

Download the Python replay · Download the calibration record

python reproduce.py --inputs STRAIN_FOLDER --out replayed-evidence.js

How it fits with prior work and what to test next

The LIGO–Virgo–KAGRA spectroscopy study used richer signal models and noise tests to assess the overtone in GW250114. In earlier work on GW150914, Cotesta and colleagues tested start-time sensitivity with injections, Isi and Farr reported different results, and Finch and Moore marginalized over timing and sky uncertainty. The general look-elsewhere effect is well established.

This lead measures separate costs for span and spacing in one explicit family of correlated tests. The candidate fits keep mass and spin fixed and let each instrument fit its own phase and amplitude. The thresholds apply to the rules, noise records and model on this page. Measuring the actual merger and accounting for uncertainty in detector calibration and waveform parameters would require a different test.

The next test is to repeat the comparison on simulated mergers in additional detector epochs, with an independently estimated merger time and a coherent network model. That would test whether the gain from keeping early cuts covers the higher threshold when the early waveform can also be wrong.